Dipòsit Digital de Documents de la UAB 5 registres trobats  La cerca s'ha fet en 0.02 segons. 
1.
8 p, 664.1 KB Cardiac activation-repolarization patterns and ion channel expression mapping in intact isolated normal human hearts / Opthof, Tobias (University Medical Center Utrecht) ; Remme, Carol Ann (Heart Center Amsterdam) ; Jorge, Esther (Hospital de la Santa Creu i Sant Pau (Barcelona, Catalunya)) ; Noriega, Francisco (Hospital de la Santa Creu i Sant Pau (Barcelona, Catalunya)) ; Wiegerinck, Rob F. (Hospital de la Santa Creu i Sant Pau (Barcelona, Catalunya)) ; Tasiam, Arlin (Heart Center Amsterdam) ; Beekman, Leander (Heart Center Amsterdam) ; Alvarez-Garcia, Jesus (Hospital de la Santa Creu i Sant Pau (Barcelona, Catalunya)) ; Munoz-Guijosa, Cristian (Hospital de la Santa Creu i Sant Pau (Barcelona, Catalunya)) ; Coronel, Ruben (Fondation Bordeaux Université) ; Cinca, Juan (Institut d'Investigació Biomèdica Sant Pau) ; Universitat Autònoma de Barcelona
The repolarization pattern of the human heart is unknown. The purpose of this study was to perform a multisite analysis of the activation-repolarization patterns and mRNA expression patterns of ion channel subunits in isolated human hearts. [...]
2017 - 10.1016/j.hrthm.2016.10.010
Heart Rhythm, Vol. 14 Núm. 2 (january 2017) , p. 265-272  
2.
5 p, 202.6 KB A leadless pacemaker in the real-world setting : The Micra Transcatheter Pacing System Post-Approval Registry / Roberts, Paul R. (Southampton General Hospital-University Hospital Southampton NHS Foundation Trust) ; Clementy, Nicolas (Centre Hospitalier Régional Universitaire de Tours-Hôpital Trousseau) ; Al Samadi, Faisal (King Salman Heart Center-King Fahad Medical City) ; Garweg, Christophe (Universitaire ziekenhuizen Leuven-Campus Gasthuisberg) ; Martinez-Sande, Jose Luis (Hospital Clínico Universitario (Santiago de Compostela, Galícia)) ; Iacopino, Saverio (Maria Cecilia Hospital) ; Johansen, Jens Brock (Odense University Hospital (Dinamarca)) ; Viñolas, Xavier (Institut d'Investigació Biomèdica Sant Pau) ; Kowal, Robert C. (Medtronic) ; Klug, Didier (Centre Hospitalier Régional Universitaire de Lille) ; Mont, Lluis (Hospital Clínic i Provincial de Barcelona) ; Steffel, Jan (Universitats Spital Zürich) ; Shelby, Li (Medtronic) ; Van Osch, Dirk (Medtronic Bakken Research Center) ; El-Chami, Mikhael F. (Emory University) ; Universitat Autònoma de Barcelona
First-in-man studies of leadless pacemakers have demonstrated high rates of implant success, and safety and efficacy objectives were achieved. Outside of the investigational setting, there are concerns, particularly over cardiac effusion and perforation, device dislodgement, infection, telemetry, and battery issues. [...]
2017 - 10.1016/j.hrthm.2017.05.017
Heart Rhythm, Vol. 14 Núm. 9 (september 2017) , p. 1375-1379  
3.
8 p, 1.3 MB Endocardial infarct scar recognition by myocardial electrical impedance is not influenced by changes in cardiac activation sequence / Amorós-Figueras, Gerard (Institut d'Investigació Biomèdica Sant Pau) ; Jorge, Esther (Centro de Investigación Biomédica en Red en Enfermedades Cardiovasculares) ; Alonso-Martin, Concepción (Institut d'Investigació Biomèdica Sant Pau) ; Traver, Daniel (Biosense Webster) ; Ballesta, Maria (Universitat Politècnica de Catalunya) ; Bragos, Ramon (Universitat Politècnica de Catalunya) ; Rosell Ferrer, Javier (Universitat Politècnica de Catalunya) ; Cinca, Juan (Institut d'Investigació Biomèdica Sant Pau) ; Universitat Autònoma de Barcelona
Measurement of myocardial electrical impedance can allow recognition of infarct scar and is theoretically not influenced by changes in cardiac activation sequence, but this is not known. The objectives of this study were to evaluate the ability of endocardial electrical impedance measurements to recognize areas of infarct scar and to assess the stability of the impedance data under changes in cardiac activation sequence. [...]
2018 - 10.1016/j.hrthm.2017.11.031
Heart Rhythm, Vol. 15 Núm. 4 (april 2018) , p. 589-596  
4.
8 p, 562.2 KB Updated performance of the Micra transcatheter pacemaker in the real-world setting : A comparison to the investigational study and a transvenous historical control / El-Chami, Mikhael F. (Emory University) ; Al-Samadi, Faisal (King Salman Heart Center - King Fahad Medical City) ; Clementy, Nicolas (Centre Hospitalier Régional Universitaire de Tours - Hôpital Trousseau) ; Garweg, Christophe (Universitaire Ziekenhuizen Leuven - Campus Gasthuisberg) ; Martinez-Sande, Jose Luis (Hospital Clínico Universitario (Santiago de Compostela, Galícia)) ; Piccini, Jonathan P. (Duke University Medical Center) ; Iacopino, Saverio (Maria Cecelia Hospital) ; Lloyd, Michael (Emory University) ; Viñolas, Xavier (Institut d'Investigació Biomèdica Sant Pau) ; Jacobsen, Michael Dilou (University of Copenhagen) ; Ritter, Philippe (Université Bordeaux) ; Johansen, Jens Brock (Odense University Hospital (Dinamarca)) ; Tondo, Claudio (University of Milan) ; Liu, Fang (Medtronic. plc) ; Fagan, Dedra H. (Medtronic. plc) ; Eakley, Alyssa K. (Medtronic. plc) ; Roberts, Paul R. (University Hospital Southampton NHS Foundation Trust (Regne Unit)) ; Universitat Autònoma de Barcelona
Early results of the Micra Investigational Device Exemption (IDE) study and Micra Post-Approval Registry (PAR) demonstrated excellent safety and efficacy performance; however, intermediate-term results across a large patient population in the real-world setting have not been evaluated. [...]
2018 - 10.1016/j.hrthm.2018.08.005
Heart Rhythm, Vol. 15 Núm. 12 (december 2018) , p. 1800-1807  
5.
7 p, 1.0 MB Impact of electrode tip shape on catheter performance in cardiac radiofrequency ablation / Petras, Argyrios (RICAM, Austrian Academy of Sciences, Linz, Austria) ; Moreno Weidmann, Zoraida (Institut d'Investigació Biomèdica Sant Pau) ; Echeverría Ferrero, Marina (Basque Center for Applied Mathematics) ; Leoni, Massimiliano (RICAM, Austrian Academy of Sciences, Linz, Austria) ; Guerra Ramos, José María (Universitat Autònoma de Barcelona. Departament de Medicina) ; Gerardo-Giorda, Luca (RICAM, Austrian Academy of Sciences, Linz, Austria)
The role of catheter tip shape on the safety and efficacy of radiofrequency (RF) ablation has been overlooked, although differences have been observed in clinical and research fields. The purpose of this study was to analyze the role of electrode tip shape in RF ablation using a computational model. [...]
2022 - 10.1016/j.hroo.2022.07.014
Heart Rhythm O2, Vol. 3 (august 2022) , p. 699-705  

Us interessa rebre alertes sobre nous resultats d'aquesta cerca?